Upgrade
Follow the steps below to perform an upgrade.
See Upgrading from 3.4 to 4.0 for more details upgrading from 3.x to 4.x.
The MySQL JDBC driver is no longer included with the Intelligence Hub. If you use MySQL connections, you must download and install the driver after upgrading. See Installing the MySQL JDBC Driver.
- Stop HighByte Intelligence Hub if it is currently running
- Running as a Windows Service: use
uninstallwindows-service.batcommand. - Running on Linux, Mac or on Windows as an app: use
stop-[OS]command.
- Running as a Windows Service: use
- Backup the application data and store and forward directories in a zip. This is best practice in the event the upgrade fails, or you decide to downgrade.
- Install a fresh copy of the latest version to a new folder (e.g.,
/HighByte/IntelligenceHub-x.x). - Copy the appData from the old installation into the new installations appData directory.
- If you added any JDBC drivers to the
runtime/libdirectory of the old installation, copy them into theruntime/libdirectory of the new installation.
- If you added any JDBC drivers to the
- Launch the new installation. This will perform any upgrades required by the latest version of the product.
Downgrade
To downgrade to an older version perform the following steps. Note: It is important to backup the application data and store and forward files before each upgrade, as files may be updated and no longer compatible with older versions.
- Unzip or backup the original application data and store and forward directories.
- Run the older version, and make sure appData and store and forward directories set in the
intelligencehub-settings.jsonpoint to the original directories.